CAGZ00ITA Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : University of Cagliari DICAAR GNSS Date Prepared : 2022-05-06 Report Type : UPDATE If Update: Previous Site Log : cagz00ita_20220505.log Modified/Added Sections : 11, 12 1. Site Identification of the GNSS Monument Site Name : Cagliari Four Character ID : CAGZ Monument Inscription : IERS DOMES Number : 12725M004 CDP Number : (A4) Monument Description : stable pillar on the ground Height of the Monument : 1.5 m Monument Foundation : CONCRETE BLOCK WITH STEEL RODS Foundation Depth : 0.5 m Marker Description : BRASS FORCE FIT Date Installed : 1995-02-01 Geologic Characteristic : BEDROCK Bedrock Type : IGNEOUS Bedrock Condition : JOINTED Fracture Spacing : 0 cm Fault zones nearby : NO Distance/activity : (multiple lines) Additional Information : Exact date in Feb 1995 not known 2. Site Location Information City or Town : Capoterra State or Province : Sardinia Country : Italy Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 4893380.225 Y coordinate (m) : 772650.197 Z coordinate (m) : 4004179.763 Latitude (N is +) : +390809.19 Longitude (E is +) : +0085821.92 Elevation (m,ellips.) : 238.0 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : JPS EUROCARD Satellite System : GPS+GLO Serial Number : LE2998 Firmware Version : MT310305520 Elevation Cutoff Setting : 5 deg Date Installed : 2001-10-01 Date Removed : 2003-08-11 Temperature Stabiliz. : 20.0 +/- 2.0 Additional Information : Exact date in October not known 3.2 Receiver Type : JPS E_GGD Satellite System : GPS+GLO Serial Number : LE4687 Firmware Version : AGNV7TGA2O0 Elevation Cutoff Setting : 5 deg Date Installed : 2003-08-11 Date Removed : 2004-04-08 Temperature Stabiliz. : 20.0 +/- 2.0 Additional Information : Spare receiver until repair of 3.1 3.3 Receiver Type : JPS E_GGD Satellite System : GPS+GLO Serial Number : 235-1757 Firmware Version : AE82EUA01KW Elevation Cutoff Setting : 5 deg Date Installed : 2004-04-08 Date Removed : 2004-05-08T10:30Z Temperature Stabiliz. : 20.0 +/- 2.0 Additional Information : Spare receiver until repair of 3.1 3.4 Receiver Type : JPS EUROCARD Satellite System : GPS+GLO Serial Number : LE2998 Firmware Version : MT310305520 Elevation Cutoff Setting : 5 deg Date Installed : 2004-05-17T11:00Z Date Removed : 2004-07-26T13:30Z Temperature Stabiliz. : 20.0 +/- 2.0 Additional Information : re-installing of the receiver 3.1 3.5 Receiver Type : JPS E_GGD Satellite System : GPS+GLO Serial Number : 235-2098 Firmware Version : AE6A2FQG160 Elevation Cutoff Setting : 5 deg Date Installed : 2004-07-26T14:30Z Date Removed : 2004-12-01T12:00Z Temperature Stabiliz. : (deg C) +/- (deg C) Additional Information : Spare receiver until repair of 3.4 3.6 Receiver Type : JPS E_GGD Satellite System : GPS+GLO Serial Number : LE4687 Firmware Version : AGNV7TGA2O0 Elevation Cutoff Setting : 5 deg Date Installed : 2004-12-01T14:00Z Date Removed : 2007-11-07T15:00Z Temperature Stabiliz. : 20.0 +/- 3.0 Additional Information : receiver 3.2 : Case label: TOPCON LEGACY-E 3.7 Receiver Type : TPS E_GGD Satellite System : GPS+GLO Serial Number : AGNV7TGA2O0 Firmware Version : 2.4 Sep,02,2004 Elevation Cutoff Setting : 5 deg Date Installed : 2007-11-07T15:00Z Date Removed : 2007-11-15T12:36Z Temperature Stabiliz. : 20.0 +/- 3.0 Additional Information : receiver 3.2 : Case label: TOPCON LEGACY-E 3.8 Receiver Type : TPS E_GGD Satellite System : GPS+GLO Serial Number : AGNV7TGA2O0 Firmware Version : 2.6 Mar,16,2006 Elevation Cutoff Setting : 5 deg Date Installed : 2007-11-15T12:36Z Date Removed : 2007-11-30T12:00Z Temperature Stabiliz. : 20.0 +/- 3.0 Additional Information : receiver 3.2 : Case label: TOPCON LEGACY-E 3.9 Receiver Type : TPS E_GGD Satellite System : GPS+GLO Serial Number : AGNV7TGA2O0 Firmware Version : 3.1 Mar,13,2007 p2 Elevation Cutoff Setting : 5 deg Date Installed : 2007-11-30T12:00Z Date Removed : 2008-11-20T15:20Z Temperature Stabiliz. : 20.0 +/- 3.0 Additional Information : receiver 3.2 : Case label: TOPCON LEGACY-E 3.10 Receiver Type : TPS E_GGD Satellite System : GPS+GLO Serial Number : AGNV7TGA2O0 Firmware Version : 3.3 Jul,10,2008 p4 Elevation Cutoff Setting : 5 deg Date Installed : 2008-11-20T21:37Z Date Removed : 2013-09-22 Temperature Stabiliz. : 20.0 +/- 3.0 Additional Information : receiver 3.2 : Case label: TOPCON LEGACY-E 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : JPSREGANT_DD_E2 NONE Serial Number : RRA052 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0945 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : RG214 Antenna Cable Length : 30 m Date Installed : 2001-10-01 Date Removed : 2013-09-22 Additional Information : Exact date in October not known. : The former valuation : Marker->ARP Up Ecc. = 0.1095 : was wrong (ARP misundertood). 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : SLR, marker O Tied Marker Usage : MOBILE SLR Tied Marker CDP Number : 7545 Tied Marker DOMES Number : 12725M002 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : 17.891 m dy (m) : 23.152 m dz (m) : -38.814 m Accuracy (mm) : 10 mm Survey method : GPS CAMPAIGN Date Measured : 2003-05-12 Additional Information : (multiple lines) 5.2 Tied Marker Name : CAGL Tied Marker Usage : EPN permanent station Tied Marker CDP Number : (A4) Tied Marker DOMES Number : 12725M003 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -1.146 m dy (m) : -0.691 m dz (m) : 2.137 m Accuracy (mm) : 5 mm Survey method : GPS CAMPAIGN Date Measured : 2003-05-12 Additional Information : Responsible agency ASI 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : EXTERNAL CAESIUM OSCILLATOR Input Frequency : 10 MHz Effective Dates : 2004-12-01/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : SLR Status : MOBILE Effective Dates : 1985-05-12/1993-12-15 Notes : MTLRS, TLRS1 7.2 Instrumentation Type : SLR Status : PERMANENT Effective Dates : 1993-12-01/2002-11-01 Notes : (multiple lines) 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : HMP 35D Manufacturer : VAISALA Serial Number : Data Sampling Interval : 60 sec Accuracy (% rel h) : 3 % rel h Aspiration : NATURAL Height Diff to Ant : 0.416 m Calibration date : (CCYY-MM-DD) Effective Dates : 2005-02-15/CCYY-MM-DD Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PTB 100 Manufacturer : VAISALA Serial Number : Data Sampling Interval : 30 sec Accuracy : 1 hPa Height Diff to Ant : 0 m Calibration date : (CCYY-MM-DD) Effective Dates : 2005-02-15/CCYY-MM-DD Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : HMP 35D Manufacturer : VAISALA Serial Number : Data Sampling Interval : 60 sec Accuracy : 0.1 deg C Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : 0.416 m Calibration date : (CCYY-MM-DD) Effective Dates : 2005-02-15/CCYY-MM-DD Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : University of Cagliari : Department of Civil and Environmental : Engineering and Architecture Preferred Abbreviation : DICAAR Mailing Address : Via Marengo 2 : 09123 Cagliari : Italy Primary Contact Contact Name : University of Cagliari DICAAR GNSS Telephone (primary) : Telephone (secondary) : Fax : E-mail : gnss_dicaar@unica.it Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : BKG Secondary Data Center : ASI URL for More Information : http://topografia.unica.it Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : http://www.ca.astro.it Additional Information : (multiple lines) Antenna Graphics with Dimensions JPSREGANT_DD_E +------------------------+ <---------- Plastic Housing for / ------------------ \ Antenna/Choke Ring / / + \ \ <-- 0.1186 L2 +---------+ | + | +---------+ <-- 0.1131 L1 | +-------------------------------------------------+ | <-- 0.xxxx TCR / | | \ \+-----------------------------------------------------+/ |+-----------------------------------------------------+| <-- 0.xxxx BCR \______________ | | ______________/